Stainless steel fixed magnetic box is a kind of equipment used in industrial production to remove ferromagnetic impurities to protect mechanical equipment and improve product quality. Although they are generally very durable, they may also encounter some common faults during long-term use. Here are some possible faults and corresponding repair methods:
1. Weakened magnetic force:
- Cause: Deterioration of magnet performance or increase in distance between magnet and impurities.
- Repair method: Check whether the magnet is damaged or whether the position of the magnet needs to be readjusted.
2. Incomplete removal of impurities:
- Cause: Improper design of magnetic box or insufficient magnetic force.
- Repair method: Clean impurities in magnetic box, check whether magnetic force is sufficient, and replace magnet if necessary.
3. Leakage of box:
- Cause: Poor seal or cracking of weld.
- Repair method: Check and repair seals and re-weld if necessary.
4. Loose fixing bolts:
- Cause: Vibration or improper installation.
- Repair method: Check and tighten bolts regularly.
5. Magnets fall off:
- Cause: The magnets are not fixed firmly or the magnets are subjected to strong impact.
- Repair method: Re-fix the magnets and make sure to use appropriate fixings.
6. Difficult to clean:
- Cause: The design is not conducive to cleaning or impurities accumulate.
- Repair method: Design a magnetic box that is easy to clean and clean it regularly.
7. Increased noise:
- Cause: Bearing wear or collision of magnets with metal impurities.
- Repair method: Check and replace worn bearings and ensure that there is enough clearance between the magnets and metal impurities.
8. Abnormal temperature:
- Cause: Overheating of the magnets or high ambient temperature.
- Repair method: Check the ventilation of the magnetic box and ensure that the ambient temperature is appropriate.
9. Corrosion on the surface of the magnetic box:
- Cause: Stainless steel material is affected by corrosive substances.
- Repair method: Clean the surface and polish or replace parts if necessary.
10. Difficult to operate:
- Cause: Wear of the operating mechanism or unreasonable design.
- Repair method: Check and replace worn parts and optimize the operating design.
When performing repairs, the following safety and maintenance guidelines should be followed:
- Before performing any repair work, make sure the magnetic box is powered off and completely stopped.
- Use appropriate tools and protective equipment.
- Perform maintenance checks regularly to prevent potential failures.
- If you are unsure how to perform a repair, you should consult a professional technician or contact the manufacturer.
Ningbo Yongshengcheng Magnetic Technology Co., Ltd. is a manufacturer of stainless steel fixed magnetic box. Remember that regular maintenance and inspections can greatly extend the service life of the stainless steel fixed magnetic box and reduce the possibility of failure.
https://www.cnysckj.com/1000kg-fixed-magnetic-box.html
https://www.cnysckj.com/800kg-fixed-magnetic-box.html
https://www.cnysckj.com/600kg-fixed-magnetic-box.html
https://www.cnysckj.com/1350kg-fixed-magnetic-box.html
https://www.cnysckj.com/What-are-the-common-faults-and-repair-methods-of-stainless-steel-fixed-magne
Ningbo Yongshengcheng Magnetic Technology Co., Ltd.